single output switching power supply 12V 12.5A 100~120V/200~240V AC input LED power supply 150W 12V transformer
Related Product Searches:single output switching power supply 12V 12.5A 100~120V/200~240V AC input LED power supply 150W 12V transformer,High Quality Switching Power Supply,Switching Power Supply S-150
Single Output Switching Power Supply
High efficiency, high reliability AC input 110VAC,220VAC select by switch Protections: Short circuit/Over load/Over voltage
Single Output S-150 Series Feature: High efficiency, high reliability, lost costUniversal AC input range selected by switch100% full load burn-in testLED indicator for power onProtections: Short circuit/Over load/Over voltageCooling by free air conventionFixed switching frequency at 25 KHz1 year warranty | |||||||
Model | S-150-5 | S-150-12 | S-150-24 | S-150-48 | |||
Output | DC Voltage | 5V | 12V | 24V | 48V | ||
Voltage Tolerance | ±2% | ±1% | ±1% | ±1% | |||
Rated Current | 30A | 12.5A | 6.5A | 3.2A | |||
Current Range | 0-30A | 0-12.5A | 0-6.5A | 0-3.2A | |||
Rated Power | 150W | 150W | 156W | 153W | |||
Ripple & Noise | 150mVp-p | 180mVp-p | 240mVp-p | 240mVp-p | |||
DC Adjustment Range | -10%,+12% | -20%,+10% | -20%,+10% | -15%,+17% | |||
Setup, Rise, Hold Time | 200ms,50ms,30ms at full load | ||||||
Input | Voltage Range | 85-132VAC/170-264VAC 47-63Hz; Selected by switch 255-370VDC | |||||
AC Current | 4.5A/115V 2.5A/230V | ||||||
Efficiency | 80% | 81% | 84% | 85% | |||
Inrush Current | Cold start 25A/115VAC 50A/230VAC | ||||||
Leakage Current | less than 3.5mA/240VAC | ||||||
Protection | Over Load | 105%-150% | |||||
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed | |||||||
Over Voltage | 115%-135% | ||||||
Protection type: Shut down o/p voltage , recovers automatically after fault condition is removed | |||||||
Environment | Working Temp., Humidity | -10 °C- +60 °C; 20%-90% RH | |||||
Storage Temp., Humidity | -20 °C- +85 °C;10%-95 %RH | ||||||
Vibration | 10-500Hz,2G 10min./1cycle, period for 60 min, each along X, Y, Z axes | ||||||
Safety | Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | ||||||
Standard | Safety Standard | Design refer to UL1012, UL60950,UL1950 | |||||
EMC Standard | Design refer toEN55022, IEC801-2,3,4 | ||||||
Others | Weight | 0.80Kg | |||||
Packing | 199*110*50(L*W*H) |