Yueqing Heyi Electrical Co., Ltd.
Main products:TRANSFORMER,CURRENT TRANSFORMER,PANEL METER,Magnetic Contactor,Power supply switch
Products
Contact Us
  • Contact Person : Ms. Cai Bethy
  • Company Name : Yueqing Heyi Electrical Co., Ltd.
  • Tel : 86-0577-62659558
  • Fax : 86-0577-62659558
  • Address : Zhejiang,YUEQING,#21 SHANGYOU NORTH ROAD,HUANGHU LIUSHI
  • Country/Region : China
  • Zip : 325604

single output switching power supply 12V 12A 100~120V/200~240V AC input LED power supply 145W 12V transformer

single output switching power supply 12V 12A 100~120V/200~240V AC input LED power supply 145W 12V transformer
Product Detailed
Single output switching power supply High efficiency, high reliability Universal AC input 110VAC,220VAC LED power supply

Single Output Switching Power Supply

Single Output S-145 Series

Feature:

High efficiency, high   reliability, lost costUniversal AC input range selected by switch100% full load burn-in testLED indicator for power onProtections: Short circuit/Over load/Over voltageCooling by free air conventionFixed switching frequency at 25 KHz1 year warranty        

Model

S-145-5

S-145-12

S-145-15

S-145-24

Output

DC Voltage

5V

12V

15V

24V

Voltage Tolerance

±2%

±1%

±1%

±1%

Rated Current

25A

12A

9.6A

6A

Current Range

0-25A

0-12A

0-9.6A

0-6A

Rated Power

125W

144W

144W

144W

Ripple & Noise

100mVp-p

120mVp-p

120mVp-p

150mVp-p

DC Adjustment Range

±10%

-12%,+10%

-12%,+10%

-12%,+16%

Setup, Rise, Hold Time

100ms,50ms,20ms at full load

Input

Voltage Range

85-132VAC/170-264VAC 47-63Hz; Selected by switch 255-370VDC

AC Current

3.2A/115V   1.6A/230V

Efficiency

78%

80.5%

81%

83.5%

Inrush Current

Cold start 30A/115VAC   60A/230VAC

Leakage Current

less than 3.5mA/240VAC

Protection

Over Load

135%-165%

Protection type: Shut down o/p voltage, recovers automatically   after fault condition is removed

Over Voltage

115%-135%

Protection type: Shut down o/p   voltage , recovers automatically after fault condition is removed

Environment

Working Temp., Humidity

-10 °C- +60 °C; 20%-90% RH

Storage Temp., Humidity

-20 °C- +85 °C;10%-95 %RH

Vibration

10-500Hz,2G 10min./1cycle, period for 60 min, each along X, Y, Z   axes

Safety

Withstand Voltage

I/P-O/P:1.5KVAC   I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation Resistance

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC

Standard

Safety Standard

Design refer to UL1012

EMC Standard

Design refer toEN55022, IEC801-2,3,4

Others

Weight

0.71Kg

Dimensions

199*98*38mm(L*W*H)



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.